Number of power phases
|
4 to 12
|
Voltage input specifications Range
|
1000 V (±2000 VPEAK )
|
Accuracy DC
|
± 0.02 % of reading ± 0.02 % of range
|
Accuracy 45 Hz - 1 kHz
|
± 0.02 % of reading ± 0.01 % of range
|
Accuracy 1 kHz - 5 kHz
|
± 0.1 % of reading ± 0.05 % of range
|
Accuracy 5 kHz - 10 kHz
|
± 0.3 % of reading ± 0.05 % of range
|
Accuracy 10 kHz - 50 kHz
|
± 0.3 % of reading ± 0.1 % of range
|
Accuracy DC
|
± 0.05 % of reading ± 0.05 % of range
|
Accuracy 45 Hz - 1 kHz
|
± 0.02 % of reading ± 0.01 % of range
|
Accuracy 1 kHz - 10 kHz
|
± 0.1 % of reading ± 0.05 % of range
|
Accuracy 10 kHz - 50 kHz
|
± 0.3 % of reading ± 0.1 % of range
|
Fundamental frequency Range
|
0.2 Hz – 20 kHz (>1 MS/s: 0.5 – 20 kHz)
|
Accuracy
|
± 0.01 % of reading ± 1 mHz
|
Voltage and current RMS/AVG/PP/PHI
|
Cycle-by-Cycle, total and fundamental
|
Active/reactive/apparent power
|
Cycle-by-Cycle, total and fundamental
|
Voltage and current unbalance
|
Cycle-by-Cycle, fundamental
|
Energy
|
T otal and fundamental / sum, positive and negative
|
T otal and fundamental / sum, positive and negative
|
IEC61400-21
|
Dimensions (W x D x H) without feet
|
441 x 427 x 177 mm, 17.4 x 16.8 x 7 inch, (4u)
|
Weight
|
Typ. 13 kg (28.6 lb.) without modules
|